PURITAN BENNETT MODEL 840 VENTILATOR

USED EXCELLENT CONDITION !!!

$7,500.00

-25%

$10,000.00

Overview

Promote more natural breathing with innovative features

We believe ventilation can and should be more natural.

Our PAV+™ software is a breath type that better manages a patient’s work of breathing and supports more natural breathing compared to conventional mechanical ventilation.^

In addition to PAV+™ software, the Puritan Bennett™ 840 ventilator also features a full suite of software options, safety features and accessories to fit a variety of patient needs, from infant to adult.

Features:

The Puritan Bennett™ 840 ventilator features our PAV+™ software, a breath type that better manages a patient’s work of breathing and supports more natural breathing compared to conventional mechanical ventilation.^

With the addition of optional advanced technology upgrades, this ventilator can meet the specific needs of practically every patient type you care for — from neonatal patients weighing as little as 300 grams to adult patients weighing as much as 150 kg.

With the Puritan Bennett™ 840 ventilator, Medtronic:

  • Provides clinically exceptional technology that helps keep patients and clinicians safe
  • Protects capital investment with an upgradeable pathway
  • Focuses on service, support and education
  • Enables the benefits of fleet standardization

Covidien 840 Specifications

Dimensions

  • Height: 56 In (142.24 cm)
  • Width (Wheels in outmost position): 28.5 In (72.39 cm)
  • Depth (Wheels in outmost position): 29.5 In (74.93 cm)
  • Weight: 162.7 lbs (73.8 kg)

Battery

  • Operating Time: A new, fully charged 1-hour BPS can operate the ventilator for at least one hour. This 1-hour BPS will not run the compressor or a humidifier. It is recommended that the 1-hour battery pack be replaced every two years.
  • Recharge Time: 20-Hours while connected to AC Power

Gas Mixing System

  • Range of flow from the mixing system: Can be set to 150 L/min standard temperature and pressure, dry (STPD). Additional flow is available (up to 30 L/min for neonatal circuit type, up to 80 L/min for pediatric circuit type, and up to 200 L/min for adult circuit type) for compliance compensation.
  • Leakage from one gas system to another: Meets standard
  • Operating pressure range: 35 to 100 psi (241 to 690 kPa)
  • Air/oxygen regulator bleed: Up to 3 L/min

Oxygen and Air Inlet Supplies

  • Pressure: 241 to 690 kPa (35 to 100 psi)
  • Flow: Maximum of 200 L/min

Max Limited Pressure

  • 127.5 cmH2O (125 hPa)

Max Working Pressure

  • 100 cmH2O (98.1 hPa), ensured by high pressure limit
  • 90 cmH2O (pressure-based ventilation)

Minute Volume (VE TOT) Capability

  • 25 to 75 L/min

Bacteria Filter Efficiency

  • 99.97% for nominal particle size of 0.3 μm (micron) at 100 L/min

Monitored Data

  • Breath type, delivered O2, end expiratory pressure, end-inspiratory pressure, exhaled minute volume, exhaled tidal volume, I:E ratio, maximum circuit pressure, mean circuit pressure, spontaneous minute volume, total respiratory rate, rapid shallow breathing index, spontaneous respiratory time.

General

  • Modes: Assist/Control, synchronous intermittent mandatory ventilation, or spontaneous
  • Respiratory Rates: 1.0 to 100/min
  • Inspiratory Pressure: 5 to 90 cm H2O
  • Inspiratory Time: 0.2 to 8.0 seconds
  • I:E Ratio: ≤ 1:299-4.00:1
  • Expiratory Time: Te ≥ 0.2 second
  • PEEP: 0 to 45 cm H2O
  • Apnea Insp. Pressure: 5 to 90 cm H2O
  • Apnea Insp. Time: 0.2 to 8.0 seconds
  • Apnea Interva:l 10 to 60 seconds
  • Apnea Resp. Rate: 2.0 to 40/min
  • Apnea I:E Ratio: ≤ 1.00:1
  • Apnea Exp. Time: ≥ 0.2 second

Alarm Limits

  • High Circuit Pressure: 7 to 100 cm H2O
  • High Exhaled Min. Vol: 0.1 to 99.9L or OFF
  • High Exhaled Tidal Vol: 50 to 3000mL or OFF
  • High Respiratory Rate: 10 to 110/min or OFF
  • Low Exhaled MandatoryTidal Vol: 5 to 2500 mL or OFF
  • Low Exhaled Min. Vol: 0.01 to 60.0L
  • Low Exhaled Spontaneous Tidal Vol: 5 to 2500 mL or OFF

Environmental Specifications

  • Pneumatic Gas Scource: Air and Oxygen: : Must be supplied at 35-100 psi (241-690 kPa)
  • Operating Temperature: 50ºF to 104ºF (10ºC to 40ºC) at 10% to 95% relative humidity, noncondensing
  • Storage Temperature: -4ºF to 122ºF (-20ºC to 50ºC) at 10% to 95% relative humidity, noncondensing
  • Operating Atmospheric Pressure: 10.2 to 15.4 psi (700 to 1,060 hPa)
  • Storage atmospheric Pressure: 7.3 to 15.4 psi (500 to 1,060 hPa)
  • Operating Altitude: 7.3 to 15.4 psi (500 to 1,060 hPa)
  • Storage Altitude: up to 20,000 ft (up to 6,560 m)